Sign up for our newsletter
Killer deals delivered daily
Be the first to know about exclusive, limited-time, and limited-quantity deals.
The DBX-RM160 is a combo unit combining two dbx 160 units into a single rackmount device.
The dbx 160 is a single-channel compressor/limiter combining sophisticated technology and user-oriented features in a compact package. Unique circuit designs, such as true rms level-detection and feed-forward gain reduction, place the 160 in a completely different class from conventional compressor/limiters.
The dbx technique of true rms level-detection gives you audible benefits. Most compressor/limiters use some form of peak detection, with fast response characteristics that can have a disturbing effect on program material. True rms level detection closely simulates the response of the human ear. Even at high compression ratios, the gain changing action of the 160 Series is highly listenable and natural sounding.
Because of the unique feed-forward approach, dbx 160 limiters can achieve infinite compression with complete stability and inaudible distortion. The dbx approach is quite unlike gain reduction in a conventional compressor/limiter. Traditional gain reduction is accomplished by sensing signal level at the device's output and applying a correction signal, via a feedback loop. At progressively higher compression ratios, the feedback loop's gain increases, distortion increases, and eventually instability or oscillation occurs. To avoid this problem, many conventional units restrict the maximum amount of feedback, thus restricting the maximum compression ratio to some lower ratio, such as 10:1 or 20:1. The dbx 160 is free of the instability of excessive loop gain, and can provide infinite compression (approximately 120: 1.) lower ratio, such as 10:1 or 20:1. The dbx 160 is free of the instability of excessive loop gain, and can provide infinite compression (approximately 120: 1.)
*The wideband distortion figures appear to suggest that 3rd-harmonic distortion is dominant. Thus, an un weighted T.H.D. (Total Harmonic Distortion) figure would be similar to the 3rd -harmonic value. However, the specific breakdown of distortion is more informative. 3rd-harmonic distortion in the 160 Series decreases linearly as the frequency rises: at 100Hz 3rd-harmonic distortion is 1/2 the value at 50Hz, etc.
**Attack and release rates automatically vary with rate of change of program level (attack and release rates "track" the signal envelope.) Specifications are subject to change without notice.
Killer deals delivered daily
Be the first to know about exclusive, limited-time, and limited-quantity deals.
0% APR Financing
Ask the Experts
Business Financing